Monitoring thermal disinfection with hygiene indicators
How do Reatec hygiene indicators document thermal disinfection?
Reatec hygiene indicators are irreversible temperature indicators, meaning they permanently change color once the temperature threshold required for thermal disinfection has been reached. This provides a visual check alongside the washer-disinfector's own cycle records. Our hygiene indicators are available in multiple configurations, covering the full temperature window for thermal disinfection (60–93 °C) in multiple steps. They are, however, not suitable for confirming sterilization temperatures, as those lie considerably above 100 °C.
How does a reaClean hygiene indicator measure the cleaning process?
The reaClean hygiene indicator performs two functions, measuring the disinfection temperature as well as showing the effectiveness of the cleaning solution and its mechanical distribution. It is outfitted with an irreversible temperature indicator which measures temperature thresholds by color change. To the left and right of that indicator, two test-soil fields are placed. During the cycle, one is fully covered by the metal indicator holder, while the other is exposed to the cleaning agent. After use, simply compare the two in order to get a visual indication of the effectiveness of the cleaning process.
Do hygiene indicators confirm the A0 value of thermal disinfection?
No, Reatec hygiene indicators do not confirm that the A0 value has been reached, since ISO 15883-1 defines it as a combination of temperature and time. They can, however, confirm that the disinfection phase reached the necessary temperature thresholds for thermal disinfection and are ideally used in combination with the process documentation from your cleaning device. A0 600 for example corresponds to 80 °C for a duration of ten minutes and our reaWash indicators can help confirm this temperature by checking for a lower threshold of 76 °C and an upper one of 82 °C. A0 3000 is recommended for critical and semi-critical medical devices by the RKI and corresponds to a holding time of two and a half minutes with a temperature of 93 °C, which our reaClean indicators match.
Which hygiene indicator should I choose?
Which hygiene indicator you should choose primarily depends on the temperature you need to check. reaClean offers an 88 °C and a 93 °C threshold while reaWash checks for three thresholds between 60 and 82 °C per indicator. The temperature thresholds you choose should sit either exactly at the required temperature for your process, bracket it or sit slightly below. Checking for the effectiveness of the cleaning process itself is also possible, since reaClean contains test-soil fields in combination with a single temperature indicator.
Where do you place hygiene indicators in a washer-disinfector?
In a washer-disinfector, you can place hygiene indicators either in the wash chamber or on the object itself which you wish to clean. Reatec offers one hygiene indicator per placement concept. reaWash is placed directly on the object and can therefore document which thresholds the surface temperature of that object reaches during the cleaning process. reaClean comes with a metal holder in which to put the indicator and can be placed anywhere in the wash chamber via its mounting brackets. reaClean therefore – in combination with its test-soil fields – acts as a test object to be cleaned along with the rest of your load while reaWash measures thresholds on actual objects to be cleaned.